標題(和) 超低圧逆浸透膜による地下水中のフッ素除去における膜ファウリングの影響
標題(洋) Effects of Membrane Fouling on Fluoride Removal from Groundwater by Ultra-Low-Pressure Reverse Osmosis Membrane
報告番号 125291
報告番号 甲25291
学位授与日 2009.09.28
学位種別 課程博士
学位種類 博士(工学)
学位記番号 博工第7135号
研究科 工学系研究科
専攻 都市工学専攻
論文審査委員 主査: 東京大学 教授 滝沢,智
 東京大学 准教授 福士,謙介
 東京大学 准教授 片山,浩之
 東京大学 准教授 徳永,朋祥
 東京大学 講師 小熊,久美子
内容要旨 要旨を表示する

Residents of Chiang Mai and Lamphun Provinces, Thailand, have been suffering from dental and skeletal fluorosis due to drinking water from the groundwater resource that contains an excessive amount of fluoride. Fluoride concentration commonly found in this region is higher than WHO's guideline value of 1.5 mg/L and Thailand fluoride standard for drinking water of 0.7 mg/L, set by The Ministry of Industry in Thailand. Although defluoridation using membrane filtration process is a new technology, it is increasingly used due to the advancement of membrane manufacturing. However, accumulation of suspended and dissolved compounds on the membrane surface results in membrane fouling such as concentration polarization and gel-layer formation. These phenomena are problems in membrane separation processes: namely, a permeate flux decline, deterioration in permeate quality and membrane degradation.

Applicability of an ultra low pressure reverse osmosis (ULPRO) membrane (UTC-70U) for groundwater defluoridation was investigated using groundwater samples obtained in Lamphun Province, Thailand. The used membrane achieved high fluoride rejections of 94.4-98.4%. Thus, the ULPRO membrane was expected to produce permeate water with a lower fluoride concentration than the standard for drinking water in Thailand (0.7 mg/L).

Effect of feed water pH on fluoride rejection was studied. The isoelectric point of the UTC-70U membrane was found at pH 5.7. This result well explained why the percentage rejection of fluoride by the charged membrane decreased at the bulk water pH below 7.0. According to the Nernst-Planck equation, the electrical potential across UTC-70U membrane (ΔΨ) at the initial feed water pH of 7.9, 7.0, 6.0, 5.0, and 4.0 was determined to be 49.1, 49.1, 44.2, 0.0, and -116 mV, respectively. Diffusion coefficient of fluoride through the membrane (Di(m)) was estimated to be 7.79x10-13 m2/s.

When groundwater samples were filtered, a fouling gel-layer was formed on the membrane surface. As a result, the rejections went up or down over the course of filtration. Fluoride concentrations at the gel-layer surface (CG) and at the membrane surface (CM) were estimated. When the fouling gel-layer is porous and can be regarded to be similar to the fluoride concentration in bulk water. Hence, back diffusion of fluoride within the gel-layer forms concentration polarization as in the water film. In this case, the ratio of CM/CG is higher than unity. On the other hand, if the gel-layer is very tight, the ratio of CM/CG is less than unity, fluoride transports by diffusion are considered to be dominant. Hence, the ratio of CM/CG can be used to estimate the characteristics of the fouling gel-layer.

Using the electrical potential across UTC-70U membrane (ΔΨ) and the diffusion coefficient of fluoride through the membrane (Di(m)), CG and CM were obtained. The change of CM/CG ratios during the filtration suggested that the difference in gel-layer structure and thickness resulted in the different trends of the fluoride rejections within groundwater samples.

Besides, the fluoride mass-transport models via diffusion mechanism were verified by filtering NaF solutions. The mass transfer coefficient of fluoride (k) in water was estimated to be 3.20 x 10-5 m/s and the solute mass transfer coefficient through UTC-70U membrane (ki) was 1.06 x 10-7 m/s. Using these mass transfer coefficients, CG and CM were estimated as well to analyzed fouling gel-layer.

Consequently, transport mechanisms of fluoride through UTC-70U membrane applied for the fouling gel-layer analysis were evaluated by considering both diffusion mechanism and the Nernst-Planck equation. The results indicated that the diffusion mechanism could be applied for the fouling gel-layer analysis of UTC-70U membrane at the feed water pH of 7.0 or higher.

Silica fouling in membrane filtration was investigated. Fouling by silica polymerization on the membrane surface without colloidal silica at the feed solution pH of 7.1 and 9.6 was not significantly different based on the permeate flux, mass of silica attached on the membrane surface, and thickness of fouling gel-layer. Silica polymerization in the presence of colloidal silica on the membrane surface at pH 9.6 is more severe than that at pH 7.1 when considering the mentioned parameters, e.g. permeate flux, mass of attached silica, and so on. Based on the evaluation of CM/CG ratios, since the ratios were higher than 1, the fouling gel-layers were fouled with loose gel-layers and the fouling gel-layer became looser when the feed water contained colloidal silica.

Although the analysis on the CM/CG ratio is a qualitative approach, the measurement of pore size and pore volume using nitrogen adsorption method was used to strengthen the application of the CM/CG ratio. The obtained results on pore size and pore volume of the fouling gel-layer were consistent with the CM/CG ratio. Thus, it was concluded that the CM/CG ratio can be applied to estimate the fouling gel-layer structure.

For a foulant extraction on the used membrane surface by ultrasonication with chemicals in series, two foulants including calcium (Ca2+) and silica (SiO2) were significantly observed. Therefore, possibility and effectiveness of fouling control including pre-filtration using microfiltration (MF) membrane with or without adding ethylenediaminetetraacetic acid (EDTA) were evaluated. It was found that EDTA addition to MF-filtered groundwater samples, i.e., twice as high as the molar concentration of divalent cations, did help to prevent Ca2+ attached on the membrane surface efficiently but did not affect silica fouling. Addition of EDTA to groundwater samples did not significantly affect to permeate fluxes, which implied that Ca2+ was not a determinant factor of the membrane fouling.

In summary, ULPRO membrane produced permeate water with a lower fluoride concentration than the standard for drinking water in Thailand at the feed water pH 7.0 or higher. The fouling gel-layer was formed on the membrane surface at filtration of groundwater samples. The CM/CG ratio was found useful in evaluating the fouling gel-layer structure. The experimental results demonstrate that colloids present in the feed water were noxious since they intensified the flux decline and gel-layer formation which deteriorated the rejection of fluoride. Hence, it is suggested that pre-filtration using MF membranes or other fouling controls could potentially minimize the colloidal fouling and improve the fluoride removal efficiency of the ULPRO process.

審査要旨 要旨を表示する

ウォンルエン・アノップ氏の研究は、「超低圧逆浸透膜による地下水中のフッ素除去における膜ファウリングの影響」と題し、タイ北部のチェンマイ盆地において高濃度のフッ素を含有する地下水を引用する住民の健康被害の低減を目的として、地下水からのフッ素除去技術としての超低圧逆浸透技術を適用し、フッ素除去率と運転操作に影響を及ぼす逆浸透膜のファウリング問題に取り組んだものである。

博士論文は8章からなり、第1章では研究の背景と目的、ならびに本論文の構成が述べられている。

第2章は文献調査であり、地下水中のフッ素濃度の分布や、フッ素による健康影響、ならびに伝統的に用いられているフッ素除去技術が述べられている。また、本研究では逆浸透法による膜ろ過技術が採用されているので、ナノろ過膜や逆浸透膜といった荷電膜の特徴と、物質移動、塩類の排除の原理が述べられている。さらに、地下水の膜ろ過において最も問題となるシリカによる膜の汚染に関連して、シリカの水中での挙動や、ポリマー化現象について、これまでに文献で報告された研究成果がまとめられている。

第3章は実験方法について述べた章であり、チェンマイ盆地における地下水サンプルの採取方法や、本研究に用いた逆浸透膜の特性、逆浸透膜ろ過実験装置の特徴と操作方法、逆浸透膜の物理的な特性の測定方法、などが述べられている。

第4章では、膜近傍での濃度分極と膜透過モデルについて、純水中にNaFおよびNaClを溶解した膜供給水を用いて、実験的に検証した。その結果、濃度分極モデルと、膜内部での濃度勾配による拡散モデルの組み合わせにより、本研究で用いた逆浸透膜によるふっ素の阻止現象がうまく説明できることが示された。また、このモデルを実際の地下水のろ過実験結果に適用したところ、膜汚染によるフッ素除去率の変動は、膜表面に形成されたゲル層の密度に関係することが示された。即ち、密度の高いゲル層が膜面に形成された場合、膜面への水の流れに伴いフッ素が運ばれるため、膜面での濃度分極がさらに激しくなり、その結果、逆浸透膜によるふっ素除去率が低下した。反対に、膜面に密度の高いゲル層が形成された場合、ゲル層内部でのふっ素の移動は主に拡散により起こるために、逆浸透膜によるフッ素除去率はむしろ上昇した。

第5章は、pHを変化させた場合の逆浸透膜によるフッ素除去率への影響を評価した。膜によるフッ素イオンの除去率は、他の一価陽イオン(Na+など)に比べてpHの影響を受けやすく、pH6以下では、フッ素除去率が大幅に低下した。この現象を説明するため、Nernst-Planck式を適用し、pHの低下により膜の荷電状態が変化することが、フッ素除去率低下の原因であることを示した。このため、フッ素除去を目的とした逆浸透膜ろ過では、炭酸カルシウムのスケール防止のためにpHを酸性にして運転することは適当でないことがわかった。

第6章は、シリカによる逆浸透膜の汚染について、地下水中のシリカ濃度と膜へのシリカの付着やシリカによる膜透過流束の低下とが単純に相関が取れない原因について調べた。膜供給水中にコロイド状態のシリカと、分子状態のシリカを割合を変えて添加し、逆浸透膜ろ過実験を行ったところ、コロイド状態のシリカが存在する場合は、存在しない場合よりも大幅に膜透過流束が低下し、フッ素の除去率も低下した。このことから、地下水(膜供給水)中にわずかな量のコロイド状シリカが存在すると、逆浸透膜の汚染が進み、フッ素除去率の低下に結びつくことが示された。

第7章は、フッ素除去に用いる逆浸透膜のファウリング制御の方法について検討した結果を述べている。ファウリング制御方法として、精密ろ過膜による前処理と、EDTA添加による処理を行った。その結果、精密ろ過膜は膜供給水中の懸濁粒子を効果的に除去し、EDTAはCa2+をキレート化するため、炭酸カルシウムによる膜汚染を抑止できることが示された。しかし、シリカの膜面への付着は抑止することができず、長期間にわたる安定的な膜ろ過運転を行うためには、シリカによる膜汚染対策が重要であることが示された。

第8章は、本研究の結論であり、上記に述べられた事柄がまとめられている。

世界には1億人以上の人がフッ素による健康影響にさらされており、ウォンルエン・アノップ氏の研究成果は、科学的な基礎に立脚しつつも、実際の浄水処理への適用を視野に入れたものであり、飲料水中のフッ素による影響を受けている人々が安全な水を利用するために役立つことが期待されている。

よって本論文は博士(工学)の学位請求論文として合格と認められる。